Portable Hg concentration in the air measuring instrument Model 431
´ë±âÁß ¼öÀº ³óµµ ÃøÁ¤±â
ultraprecision (0.013ug/m3) measuring instrument Model J 405
Application |
- Mercury Surveys and Soil Screening
- Spill Response
- Ensure Worker Safety
- Research Projects for Stack, Flue and Natural Gas
|
- Hazardous Waste Sites
- Mercury Exclusion Tests
- Monitor Disposal and Recycling of Fluorescent Lamps
- Exhaust Duct Analysis
|
Specificatio |
Resolution |
0.001 mg/m3 (405 0.013ug/m3) |
Detection Range |
0.003-0.999 mg/m3 (405 999 ug/m3) |
Precision |
5% Relative Standard Deviation at 0.100 mg/m3 |
Accuracy |
¡¾ 5% at 0.100 mg/m3 |
Response Time |
13 s in Sample Mode; 4 s in Survey Mode |
Flow Rate |
750 cc/min |
Power Requirements |
100-120 V ~ 50/60 Hz, 1 A or 220-240 V ~ 50/60 Hz, 1 A |
Internal Battery Pack |
Rechargeable nickel-cadmium |
Environmental Range |
0-40 ¡ÆC, noncondensing, nonexplosive |
Interfaces |
RS-232 PC using JCI software |
Dimensions |
6" W x 13" L x 4" H |
Weight |
7 lb |
Warranty |
One year, factory parts and labor |
Certifications |
European Communities (CE) for 220-240 V~ model only |
Àç·á³» ¼öºÐ ÇÔ·® ºÐ¼® ÀåÄ¡ Model Computrac 1000XL 2000XL 4000 XL
2009ºÎÅÍ »õ·ÎÈ÷ Ãâ½ÃµÈ 4000 XL¼öºÐÃøÁ¤ ±â´Â 1000°ú 2000ÀÇ ±â´ÉÀ» º¸°ÇÑ Á¦Ç°ÀÔ´Ï´Ù
- ¾Æ·¡ ºñ±³Ç¥ ÂüÁ¶
Water content measurement, solids content measurement , ash content measurement Model Max 5000
MAX 5000 Specificatio |
Sample Size |
200 mg to 100 g |
Resolution |
Moisture: 0.0001%; Balance: 0.0001g |
Moisture/Solids Range |
0.1% to 99.9% |
Dry Weight Range |
0-300% |
Results Display |
% Moisture, % Solids, % Ash or % Dry Weight |
Ending Criteria |
Predict (Auto or Manual), Rate, Time, Rate of Time or Reliability |
Heating Range |
25 - 600¡ÆC, Set in 1¡ÆC increments and maintained to ¡¾1¡ÆC within the range of 50 - 300¡ÆC; ¡¾2¡ÆC within the range of 300 - 600¡ÆC |
Test Parameter Memory |
250 Programs |
Program Identification |
Alphanumeric; programmable prompts for lot or product ID numbers |
Test Result Memory |
Data from last 1,000 tests and graphs from last 100 tests |
Statistical Calculation |
Mean, Standard Deviation, and Relative Standard Deviation |
Power Requirements |
100-120V ~ 50/60 Hz, 1 amp (standby) or 8 amps (heat on) |
Interfaces |
RS-232 (9-pin standard); parallel printer (LPT - PC standard); RJ-45 (Ethernet) |
Dimensions |
470mm L x 323mm W x 24mm H; 18.5" L x 12".5 W x 10" H |
Weight |
13.6 kg; 30 lbs |
Warranty |
Two years, factory parts and labor (one year international) |
Certifications |
cULus; CE |
Accessories |
Multi-Point Temperature Calibration Module; Printer; Sample Basket; Validation Package; Step Down Power Transformer
|
2010 New Version -Jerome¢ç J605 Hydrogen Sulfide Analyzer - ppb & ppt level H2S Gas Analyser
ÈÞ´ëÇü H2S
ÃÖÀú³óµµ 20 ppt (0.02 ppb)Á¤¹Ðµµ·Î ºÐ¼®
´ë±âÁß ¾ÇÃë ºÐ¼® ³ó¾÷ºÐ¾ç ³ó¾÷ ±â»ó Åä¾ç¿À¿° ºÐ¾ß
- Leak Detection
- Quality Control
- Ambient Air Analysis
- Accuracy Check for other Hydrogen Sulfide Monitors and Control Systems
- Applied Research
- Scrubber Efficiency Testing
- Hydrogen Sulfide Source Detection
- Control Room Corrosion Monitoring
- Landfills
- Agricultural Applications
- Regulatory Compliance and Permitting
- Rugged and easy to operate
- Battery powered sensor regeneration (requires external battery pack)
- Auto date/time stamp
- On board data logging 20,000 samples
- Inherently stable gold film sensor
- Pressure sensitive membrane switch operation
- Rechargeable internal battery pack for portability
- Wide detection range allows for multiple applications
- Automatic LCD backlight during low light conditions
- Survey mode for rapid source detection of hydrogen sulfide concentrations
- Microprocessor ensures a linear response throughout the entire range of the sensor
- 4-20 mA output for SCADA systems
- No PC Software Required
- 20,000 Data Points
- Stores Date, Time and Locations
- On-Board Data Logging
- Optional USB interface for data transfer and printing capabilities
- 18 Hour Battery Life
- Detects H2S levels as low as 3 ppb
- Fulfills EPA requirements
Resolution |
20 ppt in Range 0 |
Detection Range |
3 ppb -10 ppm |
Accuracy/Precision |
Range 0: ¡¾1 ppb at 5 ppb/10%RSD Range 0: ¡¾3 ppb at 50 ppb/5%RSD Range 1: ¡¾0.03 ppm at 0.5 ppm /5%RSD Range 2: ¡¾0.3 ppm at 5.0 ppm/5%RSD |
Response Time |
Manual Range Selection |
|
Range 2 (1.0 to 10.0 ppm) |
12 seconds |
Range 1 (0.10 to 1.0 ppm) |
18 seconds |
Range 0 (3 to 100 ppb) |
12 to 27 seconds |
Auto Range Mode |
12 to 52 seconds | |
Flow Rate |
150 ml/min or 0.15 l/min |
Power Requirements |
12V DC/power adapter |
Internal Battery Pack |
Rechargeable nickel metal hydride (NiMH) |
Environmental Range |
0-40¡ÆC, noncondensing, nonexplosive |
Interface |
USB |
Dimensions |
11" W x 6" L x 6.5" H/ 28 cm L x 16 cm W x 17 cm H |
Weight |
5.4 lbs / 2.5 kg |
Warranty |
1 year, factory parts and labor |
Certifications |
European Communities (CE) and TUV: UL 61010-1:2004 standard and CSA-C22.2 NO. 61010-1-04 |
Functional Test Module for instrument verification in the field
- Maintenance Kit for routine maintenance and upkeep
- Hard or Soft Field Carrying Cases for versatile handling and additional storage
- Car Adapter, External Battery Pack
|